10 Gigabit Ethernet interconnect solutions: Investigate carefully before choosing


David B. Jacobs
04.20.2009
Rating: -4.36- (out of 5)


Digg This!    StumbleUpon Toolbar StumbleUpon    Bookmark with Delicious Del.icio.us   


Editor's note: This SearchNetworking.com tip is Part 1 of the Expert Lesson, 10 Gigabit Ethernet tutorial: Connecting data centers, storage, LAN and beyond.

A wide variety of cable and interconnect types is available to support 10 Gigabit Ethernet (10 GbE). Solutions vary in terms of maximum interconnect distance, power and heat, signal latency, reliability, and adaptability to future requirements. Total cost includes more than simply the cost of equipment interfaces and cables. Labor is often a major factor. Choosing a solution requires carefully evaluating each option against your application requirements.

The basic choice is between optical fiber and copper. Until recently, 10 gigabit rates could be achieved only by using optical fiber, but now standards have been established permitting the use of twisted pair. Fiber and copper can be used in the same data center with the choice for each connection based on the distance between devices to be connected. To further complicate the decision, several options are available for both fiber and copper.

Optical fiber

Fiber options include multi-mode or single-mode fiber. Multi-mode is limited to shorter distances than single-mode. Because multi-mode cable is thicker than single-mode, portions of the light beam follow different paths as they bounce back and forth between the walls of the fiber. The result is that the signal reaching the other end of the cable is distorted. The amount of distortion increases with the length of the cable. The light beam follows a single path through thinner single-mode cable, so the amount of distortion is much lower.

Multi-mode cable was installed in the 1980s to support FDDI at 100 Mbps. This cable was 62.5 microns thick. The initial 10GBase-SR fiber interface standard was limited to 26-meter connection distances using this cable. Removi...


Digg This!    StumbleUpon Toolbar StumbleUpon    Bookmark with Delicious Del.icio.us   



RELATED CONTENT
10 Gigabit Ethernet
10 Gigabit Ethernet tutorial: Connecting data centers, storage, LAN and beyond
IBM data center networking strategy: Battle HP with partnerships
Q&A: Nortel's data networking chief discusses the future
Talking cloud computing networks and 10 Gigabit Ethernet with Arista
Nortel's VSP 9000 switch takes on Cisco, skeptical customers
Extreme offers 582 10 GbE ports in new data center switch modules
3Com hopes to win enterprise networking customers with global H3C push
Optimization of the data center with 10 Gigabit Ethernet
Converged Enhanced Ethernet: New protocols enhance data center Ethernet
Juniper adds new top-of-rack switch to data center networking line

Network Engineering
Preventing hacker attacks with network behavior analysis IPS
Internal cloud computing on the cheap: Free automated provisioning?
Improved storage performance without adding more disk
Troubleshooting -- 'Network Know-How' Chapter 17
Windows Server 2008 IP routing configuration: Static and dynamic RIPv2
Understand Windows tracert output to troubleshoot network connectivity
Using tracert and TTL to troubleshoot network connectivity problems
Optimization of the data center with 10 Gigabit Ethernet
Converged Enhanced Ethernet: New protocols enhance data center Ethernet
Test your TCP/IP protocol stack to troubleshoot network connectivity

RELATED RESOURCES
2020software.com, trial software downloads for accounting software, ERP software, CRM software and business software systems
Search Bitpipe.com for the latest white papers and business webcasts
Whatis.com, the online computer dictionary


ng and replacing installed cable is expensive, so the IEEE developed 10GBase-LRM, also known as IEEE 802.3aq. It uses a circuit that compensates for distortion. The result is that the new standard can drive signals 220 meters over 62.5 micron cable.

Cable production techniques have improved. Newly manufactured multi-mode cable is only 50 microns thick. The 10GBase-SR interface can support 300-meter connection distances with new, thinner multi-mode cable.

Single-mode fiber can carry signals up to 40 km, so it is used to connect to wide-area networks. It is more difficult to connect because of the thinness of the cable, and it requires a more expensive laser light source than multi-mode does. The result is that multi-mode is used where the connection length does not require single-mode.

Copper

10GBase-CX4, standardized by the IEEE as 802.3ak in 2002, was the first available copper interconnect for 10 GbE. Similar to copper InfiniBand cable, 10GBase-CX4 uses four cables, each carrying two-and-a-half gigabits of data. It is limited to approximately 10 to 15 meters but provides an extremely cost-effective method to connect equipment within that distance.

Small Form-Factor Pluggable Copper (SFP+CU) provides another low-cost, low-energy interconnect. It is limited to approximately 10 meters.

Twisted pair

IEEE 802.3an, more widely known as 10GBase-T, was completed in 2006 and is expected to become the most widely used 10 GbE interconnect method. It utilizes familiar twisted pair cable and RJ-45 connectors.

Current interface chips consume more power, produce more heat and introduce greater latency than fiber or earlier copper interfaces. The same problems were encountered with initial Gigabit Ethernet twisted pair interfaces, so it is expected that second (and later) generation chips will improve. In the meantime, these issues have slowed 10GBase-T adoption.

In many cases, existing twisted pair cable must be replaced. Although some installations have been successful running 10 GbE over installed Category 5 cable, this is not recommended. Even if testing indicates that the cable can carry 10 megabit traffic, intermittent problems may occur in the future.

Category 6, 6a UTP or 6a F/UTP (foil wrapped UTP) is recommended. Category 6 cable is limited to 55 meters, while 6a or 6a F/UTP can support 100-meter connections. Category 6 and 6a cables are thicker than Category 5 to reduce the possibility of alien crosstalk -- that is, crosstalk between adjacent cables. Thicker cable means that conductors in adjacent cables are farther apart, reducing the possibility of crosstalk. Foil wrapping virtually eliminates the possibility of alien crosstalk for Category 6a F/UTP.

Replacing existing cable may not be as simple as pulling out one cable and putting in another. Increased cable thickness means that Category 6 cable takes up more space in cable trays. Additional trays may be necessary if there isn't enough room in the existing tray. Care must also be taken to avoid piling too many cables on top of one another. The weight can squeeze cables on the bottom and reduce the spacing between conductors.

Installation costs

Evaluate labor costs carefully. Fiber has been considered more expensive to install because care must be taken to avoid tight bends and install connectors . Twisted pair at 10 gigabit rates also requires extra care, compared with lower-bandwidth twisted pair, when attaching connectors and arranging cable in trays. Installation costs for twisted pair can increase significantly if additional trays must be installed.

Plan for the higher data rates

100 GbE is on the way. The IEEE 802.3ba committee began working on 100 GbE in 2007 and expects to complete the work in 2010. The goal is to support 40-km connections over single-mode fiber, 100 meters over multi-mode, but only 10 meters over copper. Consider installing fiber now, even if copper appears the best choice for current needs.

About the author:
David B. Jacobs of The Jacobs Group has more than 20 years of networking industry experience. He has managed leading-edge software development projects and consulted to Fortune 500 companies as well as software startups.


Rate this Tip
To rate tips, you must be a member of SearchNetworking.com.
Register now to start rating these tips. Log in if you are already a member.




DISCLAIMER: Our Tips Exchange is a forum for you to share technical advice and expertise with your peers and to learn from other enterprise IT professionals. TechTarget provides the infrastructure to facilitate this sharing of information. However, we cannot guarantee the accuracy or validity of the material submitted. You agree that your use of the Ask The Expert services and your reliance on any questions, answers, information or other materials received through this Web site is at your own risk.



Networking Solutions for Business

Alcatel-Lucent Network Business Communications Solutions

About Us  |  Contact Us  |  For Advertisers  |  For Business Partners  |  Site Index  |  RSS
SEARCH 
TechTarget provides technology professionals with the information they need to perform their jobs - from developing strategy, to making cost-effective purchase decisions and managing their organizations' technology projects - with its network of technology-specific websites, events and online magazines.

TechTarget Corporate Web Site  |  Media Kits  |  Site Map




All Rights Reserved, Copyright 2000 - 2009, TechTarget | Read our Privacy Policy
  TechTarget - The IT Media ROI Experts